Pulse amplitude, a second check beside eye pressure

The LSMU study records the intracranial pressure pulse without needles, using the Archimedes 02 monitor: two fluid-filled chambers rest on the closed eyelids for up to five minutes and record the pulse wave through them. The pulse amplitude, in mmHg, is the height of that wave. GlaucomAI uses the mean of both eyes.

GlaucomAI judges an amplitude against LSMU controls of the same age and sex, and uses it as a second check beside the pressure-based screening.

mean levelpulse amplitudetrough to peakone heartbeat
SchematicSchematic of a pulse recording. The pulse amplitude is the height of each pulse, from trough to peak. It is a different number from the level the wave sits at.
−3−2−10+1+2+3z: standard deviations from the norm (log amplitude)norm of the controlssame age and sexwell above the norm, z > 1about 1 in 6 controls
SchematicIllustrative. Among controls of one age and sex, log amplitudes spread around their norm. GlaucomAI gives a value's distance from it in standard deviations (z): z = +1.4, for example, is higher than in 92% of controls. More than 1 SD above counts as well above the norm, and about 1 in 6 controls lies there too, so this check also flags some healthy people.
Key facts
  • The amplitude is the size of a pulse, not a pressure level.
  • The pressure inside the skull reaches the back of the lamina cribrosa, where the optic nerve leaves the eye, through the fluid around the nerve. What the amplitude reflects physically, and whether it relates to that pressure, is still being confirmed with the clinic, so GlaucomAI does not read it as the pressure behind the eye.
In GlaucomAI

The Live Demo compares a pulse amplitude with the LSMU controls of the same age and sex (log amplitude against age and sex, fitted on 67 controls). More than 1 SD above that norm counts as well above it.

In the LSMU study the amplitude was 1.32× higher in NTG than in controls after adjusting for age and sex (95% CI 1.09–1.59). On its own it separates the groups with an AUC of 0.66 (95% CI 0.57–0.76): a modest signal, not a test.

Its use is as a second check beside the PAPILA-trained pressure screening. Pressure screening alone finds 47% of NTG patients with 28% of controls flagged. Adding the amplitude, either check finds 61% of NTG patients with 39% of controls flagged; requiring both finds 23% of NTG patients with 4% of controls flagged. Of the 33 NTG patients pressure screening missed, 9 had an amplitude well above the norm.

62 NTG patients and 67 controls with an amplitude. LSMU data only: no open dataset records this signal, so it is not yet validated elsewhere.