Concepts

Eye pressure (IOP)

The front of the eye is filled with aqueous humour, a clear fluid made by the ciliary body. It flows through the pupil and drains at the angle between the cornea and the iris, through the trabecular meshwork. Intraocular pressure (IOP) is set by the balance between production and drainage, and is measured in mmHg with a tonometer.

A reading above 21 mmHg is conventionally called high, because 21 is roughly the population average plus two standard deviations. The cut-off is statistical, not a safe limit.

lightdrainage angletrabecular meshworkcorneaanterior chamberaqueous humourciliary bodyirislensvitreousretinaoptic discoptic nerve → brain
SchematicAqueous humour (blue) is made behind the iris, flows through the pupil and drains at the angle.
510152025303540IOP, mmHg21 mmHgstatistically normalabout mean ± 2 SDocular hypertensionNTG: nerve damage at "normal" IOPhigh-tension glaucoma
SchematicIllustrative population distribution of IOP. Normal-tension glaucoma sits on the “normal” side of the 21 mmHg line.
Key facts
  • IOP is the only risk factor proven to respond to treatment: in the Early Manifest Glaucoma Trial, each 1 mmHg of IOP lowering cut the risk of progression by about 10%.[3]
  • One clinic reading is a snapshot. IOP changes over the day and with body position.
  • Goldmann tonometry reads falsely high on thick corneas and falsely low on thin ones.[4]
In GlaucomAI

IOP is one input of the screening model and one axis of the phenotype, where each patient's IOP is ranked against the NTG cohort.

References on this page

  1. 3.Heijl A, Leske MC, Bengtsson B, et al. Reduction of intraocular pressure and glaucoma progression: results from the Early Manifest Glaucoma Trial. Arch Ophthalmol. 2002;120(10):1268–1279. PubMed search ↗
  2. 4.Ehlers N, Bramsen T, Sperling S. Applanation tonometry and central corneal thickness. Acta Ophthalmol (Copenh). 1975;53(1):34–43. PubMed search ↗